Air compressor oil causes and repair methods of channeling
Author: 志和      Release Date:2014/6/17      View Count:2038
 

Air compressor why oil blowby fault:

 air compressor running too long.

Modification of lubricating oil air compressor used.

 dirty, waste no time smoothly from the gas storage tank is discharged.

 air compressor oil return blocked.

 air compressor cylinder sleeve and piston and piston ring wear or oil ringinstalled anti seizure, and the lubricating oil flow.

 air compressor cooling incomplete.

 engine crankcase pressure too high.

The engine oil pressure is too high.

 air compressor air inlet filter blocked or not good.

Maintenance method of air compressor oil blowby phenomenon occurs:

Air compressor lubricating oil replacement, suitable qualified.

 checking and measuring the air compressor cylinder liner, piston ring wearand damage situation and assembly, severe wear should be replaced.

 check the air compressor filter, if damaged, defective or air filterdirty, should be timely replacement of damaged parts; check the air compressor air inlet pipe is kinked or deformation, the inlet pipe has the minimum requirements for the inner diameter (Zhi and technology teacherrecommends the best in 15.9mm above).

 check back to the oil pipe bending, and whether there is a kink of disorders. The minimum return pipe diameter is 12mm is the best. The oil return pipe must have been from the air down to the engine crankcase.

Air cooling, air compressor, to remove oil, accumulated in the fins on thesoot or not clean. Find the damaged parts need to be replaced; check theradiator damage, found the damaged parts should be replaced.

Water cooling, air compressor, cooling pipes to check for proper size(minimum diameter pipeline is 9.5mm), check the coolant circulation of air compressor, the engine speed, minimum allowable flow is 5L per minute. If thecoolant flow slowly, rust, kink and limiting factors for checking the coolingpipes and fittings accumulation.

Check the water temperature should not exceed 93 degrees. Check the valvecylinder, ensure their normal operation. Suggest vehicle is equipped withautomatic exhaust valve. And in the cylinder before properly equipped withair drying air.

 test engine crankcase pressure is too high, ventilation equipmentreplacement or repair of crankcase. The oil dipstick or loose part of liftthe crankcase pressure problems.

 checking engine lubrication pressure (air compressor oil inlet), andcompared with the rated pressure.

Reminder.

Chronicles and the electromechanical device limited company to recommend air compressor, water heater, air compressor heat recovery equipment, as long as you have the air compressor factory, can 0 operation cost of producing hot water and heating.

See details > >

(this paper mainly analyzes the empty oil press reasons and maintenancemethod of, but in actual in the problem solving process is for reference only.)

 
专业提供:空压机热水器空压机余热回收空压机余热利用空气能热水器系列
Address:Qinghu cun, Qishi Town, Dongguan, Guangdong Province Tel:+86-0769-86723636 Fax:+86-0769-82820762
All rights reserved © DongGuan ZhiHe Mechanical and electrical equipment Co., LTD   
网站地图    sitemaps