Air compressor oil leakage problem answer
Author: 志和      Release Date:2014/6/17      View Count:1884
 

In the using process of the air compressor, and sometimes will appear leakage fault. So why the air compressor oil? Air compressor oil and how to handle it? Below small make up for you:

Why oil air compressor:

1, the spindle looseness caused oil seal.

2, combined with surface leakage, loose joints, into the oil return pipe.

3, the oil seal oil seal off or defect.

4, casting or machining defects.

How to deal with the air compressor oil:

1, check the oil seal, the box with the size, does not meet the criteriashould be timely replacement.

2, check and re adjust the belt tightness, is generally the thumb press 10 millimeter advisable.

3, check back to the oil inlet, joint bolt and screw and tighten the box.

4, to move the spindle neck to check the gap is too large, the gap is too large to be replaced at the same time bearing and oil seal.

Defects of 5, check the box casting or machining, repair or replacement of defective parts.

6, check the oil seal combined with the main surface has scratches and defects, there are scratches and defects should be replaced in a timely manner.

7, check the combination sealing gasket, repair or replace the gasket.

8, check back to the oil flow, poor oil return to the crankcase pressurecaused by high seal leak or fall off, must ensure that the minimum diameter of the oil return pipe, and no distortion, no bending, oil return smoothly.

9, observe the seal parts, check the oil seal if there is crack, inner lipwith or without cracking or flange. If appear above should be replaced in a timely manner.

Reminder.

Chronicles and the electromechanical device limited company to recommend air compressor, water heater, air compressor heat recovery equipment, as long as you have the air compressor factory, can 0 operation cost of producing hot water and heating.

See details > >

(leakage of the main air compressor is analyzed and solution, but in actualin the problem solving process is for reference only.)

 
专业提供:空压机热水器空压机余热回收空压机余热利用空气能热水器系列
Address:Qinghu cun, Qishi Town, Dongguan, Guangdong Province Tel:+86-0769-86723636 Fax:+86-0769-82820762
All rights reserved © DongGuan ZhiHe Mechanical and electrical equipment Co., LTD   
网站地图    sitemaps