Good air ventilation facilities compressor system
Author: 志和      Release Date:2014/4/29      View Count:2141
 

According to small make up to understand, good ventilation air compressor system,although simple, but very important, if the air compressor air compressor systemusers can do the ventilation work, so it has been largely reduce the failure rate of theair compressor, so I believe what we spend on this. Energy is worth. Whether it is oil free compressor or micro oil free air compressor, regardless of air compressor is air-cooled or water-cooled air compressor room, ventilation is very important.

Air compressor room not timely ventilation problem what is the impact on the compressor?

The air will be a lot of heat in the process of being compressed, the heat if not promptly discharge air compressor room will cause increase room temperaturepressure room air, so air compressor air inlet temperature will increase, so the vicious spiral will cause the air compressor exhaust temperature is too high and alarm, andalso because of the small air compressor density of high temperature air and willcause a decrease in gas production.

Air-cooled and water-cooled air compressor to do ventilation facilities?

The water-cooled air compressor is concerned, most of the heat through the heat exchanger to the cooling water, the cooling water will take away the heat, then only need to set the ventilation fan less take the main motor emitted a small part of the heat on the line; and for air compressor, need to have fresh air amount ofcompression process of heat in exchange, you must consider the entrance of freshwind, preferably near the entrance of air compressor cooling wind suction entrance(used for compressed air entrance part of the best can also close to the fresh airentrance). If necessary, you can set up separate channel to introduce fresh air, which can avoid the air compressor air compressor room air cooling process, of course, this depends on air compressor room structure and customer circumstances. General toset the air after heat exchange of hot air from air compressor room, if necessary, but also in the export of a fan or fan to enhance the effect of hot air is derived.

Small make up remind you: fresh air entrance mentioned above need to be arranged in air compressor room of the low, and the air outlet (including the corresponding fanor fan) to set high, because hot air density is small, the general will remain high, thiswill be beneficial to the hot air is derived, the short circuit of hot air at the same time,will prevent the discharge again into the air inlet and air flow.

Another point to note is the best fresh air entrance and hot air outlet are respectively arranged on opposite walls, the purpose of doing so is also short of hot air to preventdischarge again into the air inlet and air flow. The dust mesh to avoid more dust orcatkins from entering the air compressor room best set in the fresh air inlet, hot airoutlet is arranged in the best rain cover to avoid rain water flowing into the heat exhaust duct.

Both the air inlet or outlet duct, should avoid shrinkage or elbow is relatively large, as this will cause and effect of ventilation ventilation resistance is relatively large.Because the air pressure in the computer room air compressor has been used forcompression and cooling, and fresh air are generally passive, so the air pressureinside the room will generally maintain a certain negative pressure, this is normal. But if the pressure exceeds the allowable value indicating the need for improved air inletsize or quantity, because of the negative pressure value will cause the cooling effect is poor and the exhaust volume reduction.

Reminder.

Chronicles and the electromechanical device limited company to recommend air compressor, water heater, air compressor heat recovery equipment, as long as youhave the air compressor factory, can 0 operation cost of producing hot water andheating.

See details > >

(this paper mainly analyses how to do a good job in air compressor system ventilationfacilities, but in the actual in the problem solving process is for reference only.)

 