Check the operating procedures of screw type air compressor
Author: 志和      Release Date:2014/3/29      View Count:1721
 

In order to machine and operator safety, in the operation of the air compressoroperation, first note staff must go through training and safety training and be familiar with the air compressor structure, performance, working principle, operation procedure and air compressor etc..

Air compressor checking before starting:

 before the start, should open the exhaust valve of compressor, close the manualdrain valve, the operator should be in the safe position.

Check whether all the gas supply pipeline dredge, bolt, joint fastening.

A variety of instruments to check the low-voltage power distribution cabinet whichinstructions are correct, electrical wiring is intact, ground of compliance with the standards.

Lubricating oil check the oil and gas separator in capacity, normal operation, the oil level gauge oil surface on the middle upper and lower bounds for the best.

Operating procedures:

The boot: turn on the power switch, the power supply is switched on, to observe theoperation panel on whether there is abnormal, the phase sequence is correct, if abnormal display should be immediately cut off the power, troubleshooting before put into use, the machine has a reverse phase protection, the motor is reversed.

The start: by the control panel on the "start" button, the compressor according to the set mode operation. At this point should be on display a variety of parameters on the panel are normal, whether there is abnormal, sound, whether there is leakage,immediately stop check if necessary. Boot, the first open the main machine, about 1minutes drive from the machine.

The shutdown: by the control panel on the "stop" button, the compressor starts todischarge after a period of time, will stop, don't stop immediately is a normalphenomenon. Shutdown, should stop the machine, after the host.

④ if air compressor special abnormal situation, can press the emergency stop button,if you need to restart the 2-3 minutes.

The air compressor is strictly prohibited to start with load, or because of excessive starting current and the damage to the electrical components.

And when the air compressor when not in use, should cut off the power supply, gas supply valve closed compressor. Discharge cooler, oil water separator, the exhaust pipe and the air bag in the water.

The downtime, must open the power supply cabinet knife gate and listing, hit theground.

Reminder.

Chronicles and the electromechanical device limited company to recommend air compressor, water heater, air compressor heat recovery equipment, as long as youhave the air compressor factory, can 0 operation cost of producing hot water andheating.

See details > >

(checking operation procedure, this paper mainly analyzes the screw type air compressor in the actual in the problem solving process is for reference only.)

 
专业提供:空压机热水器空压机余热回收空压机余热利用空气能热水器系列
Address:Qinghu cun, Qishi Town, Dongguan, Guangdong Province Tel:+86-0769-86723636 Fax:+86-0769-82820762
All rights reserved © DongGuan ZhiHe Mechanical and electrical equipment Co., LTD   
网站地图    sitemaps