According to the chronicles of electromechanical equipment and technical personnel to understand, general compressor dryer can be installed in air compressor room, as long as no more than the permitted load floor, air compressor dryer without large foundation engineering can be installed. The internal cooling refrigeration drier, should pay attention to the installation site adequate ventilation.
In order to avoid the freezing of the condensed water, the room temperature should not be lower than 2 ℃, for freeze dryer, the room temperature should not be higher than 45℃.
The adsorption dryer, according to the structure types, allowable ambient temperature is between 40℃ to 60 ℃.
For the convenience of repair, bypass pipe is arranged at the recommended cut-off valve. So, it is easy to emerge from the dryer within the network, without allowing the compressed air supply interruption.
In may require repair, with repair and installation site operators enough activity space of water-cooled freeze dryer is larger, the shell and tube heat exchanger. It should be noted here, for ease of cleaning, inspection, connection pipe velocity should be easy to repair, operation speed, pipe should be able to pull out. The heat regenerative adsorption dryer, notice before installation: the height direction room also has enough distance for the replacement of electric heating rod. |