Oil free air compressor maintenance and maintenance guide
Author: www.dg-zhihe.com      Release Date:2012/11/3      View Count:7257
 

Oil free air compressor maintenance and maintenance guide

( supply: Huainan air compressor water heater, Huainan air compressor waste heat recovery )

And the mechanical and electrical equipment company limited technical personnel for oil-free air compressor maintenance and maintenance made concrete analysis, so as to make the oil free air compressor maintenance and maintenance guide.

Daily maintenance:

One, check the air filter and coolant level;

Two, check the hose and all the fittings have leakage;

Three, check the levels of intake air temperature and exhaust temperature, when necessary, cleaning the intercooler and aftercooler;

Four, check the bearing pressure and temperature, when necessary, cleaning oil cooler;

Five, check the condensed water discharge, if it is found that the displacement is too small or no condensed water discharge, must stop cleaning water separator.

Monthly maintenance:

One, check the oil cooler surface, necessary cleaning;

In two, after cleaning the cooler;

In three, the cleaning water separator;

Four, check all wires are connected and fastened by;

Five, examination of AC contactor;

Six, cleaning motor suction opening surface and the surface of the shell of dust.

Quarterly maintenance:

One, the main motor lubricating grease filling;

Two, clean the main motor and the fan motor;

In three, the replacement of oil filter;

In four, the cleaning of oil cooler;

Five, check the temperature sensor and pressure sensor.

Annual maintenance:

One, replacing the coolant;

Two, check the check valve;

Three, check the cooling fan;

Four, check the hydraulic cylinder, replace if necessary repair assembly;

Five, check valve, replace if necessary repair assembly;

Six, check all metal hose.